High Quality Products Can Be Purchased.
You are here: Home » News » Brewery Ground System Construction

Brewery Ground System Construction

Views: 18     Author: Site Editor     Publish Time: 2025-08-22      Origin: Site

Core Requirements Analysis


Regulatory Compliance

  • Must comply with food production standards such as FDA/GB 14881.

  • Good Manufacturing Practices (GMP) standards recommended by the Brewers Association (BA).

  • EU Regulation EC 1935/2004 for Food Contact Materials.


Functional Specifications

  • Chemical Resistance: At least resistant to liquids with a pH of 1-14.

  • Slip Resistance: ≥ 0.6 when wet (ASTM D2047).

  • Thermal Shock Range: -20°C to 120°C transient resistance.


750 FV-min


Comparison of floor material technologies

Material Type

epoxy resin

polyurethane

Methyl methacrylate

‌Service life‌

3-5 years

8-12 years

5-7 years

‌Curing time‌

24-72 hours

12-24 hours

2-4 hours

Temperature range‌

-10~65°C

-30~120°C

-40~90°C

Cost ($/m²)‌

25-40

45-75

60-90


750 FV-min


Drainage System Optimization Solution


Trough Drainage System

  • Recommended Width: 100-150mm (balancing drainage capacity and traffic safety).

  • Slope Design: A 1.5-2% gradient ensures self-cleaning.

  • Stainless Steel 304/316L Material Selection Criteria.


Special Area Treatments

  • Fermentation Tank Area: Additional acid-resistant coating is required.

  • Bottling Line: Integrated anti-static features are recommended.

  • Mashing Room: High-temperature resistance must be ≥150°C.


750FV2-min


Key Construction Points


Subgrade Preparation

  • Concrete strength must be ≥ C25.

  • Moisture content <4% (ASTM F1869 test).

  • Surface flatness 3mm/2m.


Coating Application

  • Primer: 100% solids epoxy penetrant coat.

  • Mid-coat: Quartz sand-reinforced wear layer (particle size 0.3-0.8mm).

  • Topcoat: Self-leveling polyurethane finish.


750 BW-min


Maintenance and Management Standards


‌Daily Cleaning‌

  • CIP cleaning pressure <5 MPa.

  • Chlorine-containing disinfectants are prohibited.

  • 70-80°C hot water is recommended for rinsing.


‌Periodic Inspection‌

  • Coating thickness inspection is conducted quarterly (standard value ≥ 3 mm).

  • Annual anti-slip performance testing is performed.

  • Full system evaluation is conducted every three years.


750 BW2-min


Innovative Solutions


Smart Floor System

  • Integrated Temperature Sensor Network

  • Automatic Leak Alarm

  • Conductive Coating for Anti-Static Design


Sustainable Materials

  • Bio-based Polyurethane (30% Renewable Raw Materials)

  • Photocatalytic Self-Cleaning Coating

  • Recycled Glass Aggregate Reinforcement



PAY ATTENTION TO US
Facebook
Twitter
Google
LinkedIn
Instagram
DEGONG DTR
Brewery - Chemicals - Chocolate - Cosmetics - Pharmacy - Industry - Agriculture - Food - Dairy
  • Whatsapp
    Fax: +86 186 1518 5568
  • Email
    info@degonget.com
  • Phone
    Toll Free: +86 531 58780867